LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
OMRON E5CN-HC2B-W AC100-240 E5CN-HC2B-W AC100-240
No PHOTO
OMRON E5CN-HC2B-W AC100-240
Name: Safety Network Controller.
No. of I/O points: Safety inputs, 16; Test outputs. 4; Safety outputs, 8.
Unit version: 1.1.
Directly Connected to SYSMAC.
CS/CJ Series via EtherNet/IP.
Monitors safety systems via EtherNet/IP.
Equipped with master functions of CIP Safety on DeviceNet.
Does not require external devices for connecting OMRON E5CN-HC2B-W AC100-240.
Safety Network Controller and EtherNet/IP.
Increased maintainability in combination with,
OMRON’s EtherNet/IP compatible PLC E5CN-HC2B-W AC100-240
ISO13849-1 (PLe) and IEC 61508 SIL3 certification. New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with,
Enhanced Functions and Performance OMRON E5CN-HC2B-W AC100-240.
Improved Indication Accuracy and,
Preventive Maintenance Function.
Indication Accuracy .
Thermocouple input: ±0.3% of PV (previous models: ±0.5%).
Pt input: ±0.2% of PV (previous models: ±0.5%).
Analog input: ±0.2% FS (previous models: ±0.5%).
A PV/SV-status display function can be set to automatically,
alternate between displaying the status of the Temperature,
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV OMRON E5CN-HC2B-W AC100-240.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter .
Three-level display that simultaneously displays the PV, SV, and MV.
One-touch operation with PF Key that can be assigned to,
auto/manual, RUN/STOP, or other functions. Output: SPDT.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.9 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 41 Pa.
Noise: 50 Hz, 47 dB; 60 Hz, 48 dB.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and concealss the hole-cut to,
simpllify installation work E5CN-HC2B-W AC100-240.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVennt Attachment E5CN-HC2B-W AC100-240.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.
E5CN-HC2B-W AC100-240 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E5CN-HC2B-W AC100-240&select=5


...more relevant model market price >>>>
Related products