Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E2E-X20MD1-M1GJ-T 0.3M.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade
E2E-X20MD1-M1GJ-T 0.3M
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON E2E-X20MD1-M1GJ-T 0.3M.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation OMRON E2E-X20MD1-M1GJ-T 0.3M.
Operating current: 0.25 to 0.5 A.
Accurate Detection of Heater Element .
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point traansfer output and remote SPP input, suitable for a wide range of applications E2E-X20MD1-M1GJ-T 0.3M.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperratture controller is connected to each other by using the component communication E2E-X20MD1-M1GJ-T 0.3M.
A new type of proportional control allows you to control the valve.
E2E-X20MD1-M1GJ-T 0.3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X20MD1-M1GJ-T 0.3M&select=5