Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON D4SL-N4NDG-DN.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
D4SL-N4NDG-DN
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction OMRON D4SL-N4NDG-DN.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions . Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Sensing method: Retro reflective.
Appearance: Vertical.
Connection method: Standard M12 Connector OMRON D4SL-N4NDG-DN.
Sensing distance: 1m [100 mm].
Model: NPN output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, -- .
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement D4SL-N4NDG-DN.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV D4SL-N4NDG-DN.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
D4SL-N4NDG-DN Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4SL-N4NDG-DN&select=5