Input type: DC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON D4SL-N3TFG.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
D4SL-N3TFG
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON D4SL-N3TFG.
DevModel : CV1000-CPU01-V1 .
SFC / Ladder 1, 024 points (with RAM62K words, the top internal link).100 to 120/200 to 240 VAC (switchable), Wired.Appearance: Round/Full-guard type A22-G.
Output: SPST-NO + SPST-NC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black) OMRON D4SL-N3TFG.
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring) .
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). No. of I/O slots: 3 slots.Actuator: Roller plunger (Metal roller).
Cable length: 5 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The usee of communicattion adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) D4SL-N3TFG.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthee basic function is complete D4SL-N3TFG.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
D4SL-N3TFG Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4SL-N3TFG&select=5