Control cycle: Yearly.
Number of outputs: 4 circuits.
Mounting method: Surface mounting/track mounting.
Supply voltage: 100 to 240 VAC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation OMRON D4SL-N2FDA-D.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days
D4SL-N2FDA-D
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment OMRON D4SL-N2FDA-D.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting .
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank function allows program switching by an external input OMRON D4SL-N2FDA-D.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series . Type: Used for connecting Ionizers.
Cable length: 790 mm.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV D4SL-N2FDA-D.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation D4SL-N2FDA-D.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
D4SL-N2FDA-D Operation manual/Instructions/Model selection sample download link: