Model : CV500-CPU01-V1.
SFC / Ladder 512 (with RAM30K words, the top internal link).Output mode: E3C-LS3R detection mode: qualified reflection type.
Detection distance: 30 positive and negative 3mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationE5CN, E5EN, E5AN, E5ZN, E5 / R software OMRON D4A-1E05N.
Can shorten the parameter setting, equipment adjustment, maintenance time
D4A-1E05N
Can use the computer to compile, edit and download all parameters.
Can reduce the parameter setting time.
Online monitoring function.
Up to 31 simultaneous monitoring of the data.
(but only in the same series of thermostat) OMRON D4A-1E05N.
Function of parameter mask (not showing the parameters that are not used) .
(E5_N, E5_R)
With CX-Programmer at the same time start and use,
Can share the folder used by CX-Programmer.
The function of the model can be automatically retrieved only by the unit number,
Trend monitoring connection function (automatic inspection function). Appearance: Square/Projection type LED lighting,
(without Voltage Reduction Unit) A22L-D OMRON D4A-1E05N.
Output: SPST-NO + SPST-NC + SPST-NC .
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulatinng material .
Cable lengths of 3 and 5 m available on standard models D4A-1E05N.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirrmation of operation D4A-1E05N.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
D4A-1E05N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4A-1E05N&select=5