Appearance: Close mounting.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity D3V-114M-2A4 Price.
Series includes models that enable switching between,
dark-ON and light-ON operation
D3V-114M-2A4
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available D3V-114M-2A4 Price.
A wide range of variations in eight different shapes .
Flexible robot cable is provided as a standard feature. Output: DPDT.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with D3V-114M-2A4 Price.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savinngs in cost and space ccompared,
with previous systems OMRON D3V-114M-2A4.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems OMRON D3V-114M-2A4.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.