Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Black.
Output: SPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness OMRON .
Three-color models (green, orange, red; chameleon lighting) D4NS-7CF
included in lineup. Optical system: positive and negative radiation.
Detection distance: 20 positive and negative 1mm.
Beam shape: linear beam.
Beam diameter: 1.0mm * 20 m.
Resolution: 0.25 M.
Cable length: 2m. Actuator: Plunger OMRON .
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action) .
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement OMRON .
Standardized gold-clad contacts provide high contact reliability .
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Power supply: DC power supply.
Output method: Relay output.
Inputs points: 18 points.
Outputs points: 12 points.I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method:: M3 terminal blockk OMRON D4NS-7CF.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wiree tterminals each,
connecting to a single wire OMRON D4NS-7CF.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.
D4NS-7CF Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=D4NS-7CF&select=5


...more relevant model market price >>>>
Related products
OMRON
Safety-door Switch
D4NS-4BF-SJ
OMRON Safety-door Switch D4NS-4BF-SJ
Type: 1-Conduit High pull-force type.
OMRON
Safety-door Switch
D4NS-8CF
OMRON Safety-door Switch D4NS-8CF
Type: 2-Conduit. Contact configuration:
OMRON
Safety-door Switch
D4NS-9AF
OMRON Safety-door Switch D4NS-9AF
Type: 1-Conduit, with connector. Contac
OMRON
Safety-door Switch
D4NS-2BF-SJ
OMRON Safety-door Switch D4NS-2BF-SJ
Type: 1-Conduit High pull-force type.