LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
E6HZ-CWZ1X 300P/R 2M OMRON E6HZ-CWZ1X 300P/R 2M
No PHOTO
OMRON E6HZ-CWZ1X 300P/R 2M
Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 12 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity OMRON E6HZ-CWZ1X 300P/R 2M.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads E6HZ-CWZ1X 300P/R 2M
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor OMRON E6HZ-CWZ1X 300P/R 2M.
Optimum SSR to control minute load, valves, and solenoids . Power ratings: 480 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 48 V.
Output current: 10 A.
Boost Current: 12 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market OMRON E6HZ-CWZ1X 300P/R 2M.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC .
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Type: DC-switching.
Contact form: 3PDT.
Open structure: Solder terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 100 to 240 VAC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 2.2 kW (11.1 A), 200 to 220 VAC.
Monitor output: ACC switching output .
Neww Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy E6HZ-CWZ1X 300P/R 2M.
Certified for UL and CSA.
Mounts with screws or to DIN Track.

Coompact design with heat sinks (3 E6HZ-CWZ1X 300P/R 2M. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.
E6HZ-CWZ1X 300P/R 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E6HZ-CWZ1X 300P/R 2M&select=5


...more relevant model market price >>>>
Related products
OMRON
Incremental rotary encoder diameter 38
E6HZ-CWZ1X
OMRON Incremental rotary encoder diameter 38 E6HZ-CWZ1X
A small, high resolution general type of