Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available OMRON DCA1-5CN05F1. )
M12-connector models are also available, saving on labor and,
simplifying replacement
DCA1-5CN05F1
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON DCA1-5CN05F1.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller) .
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC OMRON DCA1-5CN05F1.
M12-connector models are available, saving on labor and,
simplifying replacement .
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type: open type.
Structure: bottom mounting type.
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W outpput terminals)
Suupport finger touch protection to prevent electric shock DCA1-5CN05F1.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer DCA1-5CN05F1. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
DCA1-5CN05F1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=DCA1-5CN05F1&select=5