CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 12; Output, 8 OMRON D4SL-2RDA-D.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet
D4SL-2RDA-D
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams OMRON D4SL-2RDA-D. Control output 1: Voltage output.
Control output 2: Relay output.
Auxiliary output: Two .
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15 OMRON D4SL-2RDA-D. 2 mm improves visibility.
High-speed sampling at 50 ms .
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Cable Specifications: Standard cable (non-polar).
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
AC.
Minimum order: 5.
UL-listed: --.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 reequirements and ensure a,
94V-0 fire retardant rating D4SL-2RDA-D.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on D4SL-2RDA-D.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
D4SL-2RDA-D Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4SL-2RDA-D&select=5