Type: rectangle.
Screen mode: no segmentation.
Output: DPDT.
Power supply voltage: DC12V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset).
Operation Department color: White (using yellow and green LED).
In the touch and the ability to protect than OMRON''s previous models have improved OMRON D4N-2E20.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing
D4N-2E20
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection OMRON D4N-2E20.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient . Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables OMRON D4N-2E20.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications .
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance funcction is incrreased,
Further performance improvement D4N-2E20.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV D4N-2E20.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
D4N-2E20 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4N-2E20&select=5