Standard certification: No.
Insulation: photo coupler.
Zero crossing trigger function.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC4 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type) OMRON D2SW-P2L2H.
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type)
D2SW-P2L2H
A model with an action indicator to check the status of the input. (type N)Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode OMRON D2SW-P2L2H.
Control output 2: output unit mode.
Control mode: standard or heating cooling .
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON D2SW-P2L2H.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks).Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, tto see the statte of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV D2SW-P2L2H.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output D2SW-P2L2H.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
D2SW-P2L2H Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D2SW-P2L2H&select=5