Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ F3ZN-S0864N09.
Conduit size (See Note.): 1/2-14NPT
F3ZN-S0864N09
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices F3ZN-S0864N09.
(4-, 5-, and 6-contact models are available) .
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames F3ZN-S0864N09.
The plastic material makes the Slide Key suitable,
for lightweight doors. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON F3ZN-S0864N09.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON F3ZN-S0864N09.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F3ZN-S0864N09 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3ZN-S0864N09&select=5