Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia F3SJ-A0281N14. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch
F3SJ-A0281N14
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts F3SJ-A0281N14.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other .
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch F3SJ-A0281N14.
Malfunctions and false operation prevented by special Operation Key .
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1). Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight/Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 10 m.
DC: Minimum order, 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON F3SJ-A0281N14.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON F3SJ-A0281N14.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F3SJ-A0281N14 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SJ-A0281N14&select=5