E3Z-G62-S0SHW-E2 is selected for use with 1 optical axis and 15 axis type
Prevent mutual interference function, EN standard specifications
Groove type photoelectric sensor without optical axis adjustmentSize: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black E2E-S04N02-CJ-C2 0.3M.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points
E2E-S04N02-CJ-C2 0.3M
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E2E-S04N02-CJ-C2 0.3M.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors E2E-S04N02-CJ-C2 0.3M.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV .
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savinngs in cost and space compared,
with previous systems OMRON E2E-S04N02-CJ-C2 0.3M.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems OMRON E2E-S04N02-CJ-C2 0.3M.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
E2E-S04N02-CJ-C2 0.3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-S04N02-CJ-C2 0.3M&select=5