LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
OMRON G3NH-4150B AC100-240 G3NH-4150B AC100-240
No PHOTO
OMRON G3NH-4150B AC100-240
No. of poles: 5.
Connection method: Screw-on.
Suitable cable dia: 6 mm (5 to 6).
Core conductor size: 0.18 to 0.75 mm.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors OMRON G3NH-4150B AC100-240.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock G3NH-4150B AC100-240
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved OMRON G3NH-4150B AC100-240. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control .
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON G3NH-4150B AC100-240.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output .
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makess the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output G3NH-4150B AC100-240.
Through the infrared port can be carried out from the frronnt of the communication G3NH-4150B AC100-240.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
G3NH-4150B AC100-240 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G3NH-4150B AC100-240&select=5


...more relevant model market price >>>>
Related products
OMRON
Time interval table
K3HB-PPB-A1 AC100-240
OMRON Time interval table K3HB-PPB-A1 AC100-240
Input type: PNP input type. Event input
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC100-240
Category: external supply 100mA DC5V typ