Size: 96 × 96 mm.
Control type: Position-proportional control (1 loop).
Control mode: Single-loop position-proportional control (See note.).
Outputs(control/transfer): Relay output,
(1 open, 1 close) and 1 current (transfer) output.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes OMRON .
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity
F3SG-4RA1310-30
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight OMRON .
Multiloop control, cascade control, and proportional control are,
possible with a single Controller .
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) OMRON .
DeviceNet Communications.
Data setting and monitoring can be performed without special programming . Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Manual.
Output: SPST-NC + SPST-NC.
Operating voltage: 24 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using currennt converter .
Available in 7 supply voltage configurations OMRON F3SG-4RA1310-30.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection OMRON F3SG-4RA1310-30.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
F3SG-4RA1310-30 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SG-4RA1310-30&select=5