Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON F3SP-T01.
Event input points: -
F3SP-T01
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON F3SP-T01.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON F3SP-T01.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc . , can be a key operation. Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Not changeable .
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2.
Mounts to DIN Rail. Type: DC Bus Line Connector.
Number of Connectors: 10 (See note.).
DC Backup Block for S8TS Prevents 24-VDCC .
Outages Due to Power Interruptions or Failures F3SP-T01.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to acchieve a simple system configuration F3SP-T01.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant.
F3SP-T01 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SP-T01&select=5