OMRON E6B3-CWZ6C 20P/R 0.5M
Contact form: 4PDT.
Classification: Standard model.
Plug-in terminals.
Fully Sealed Version of G2A that Displays Its.
Power in Adverse Environments.
Exhibits stable performance in an adverse atmosphere of,
harmful gas, moisture, or powdery dust due to its hermetically,
sealed construction.
All the mechanical components of the Relay have been,
annealed to prevent gas generation inside the Relay E6B3-CWZ6C 20P/R 0.5M
Economical as compared with a hermetically sealed relay in a,
metallic enclosure. Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3 OMRON E6B3-CWZ6C 20P/R 0.5M. 8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None .
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments OMRON E6B3-CWZ6C 20P/R 0.5M.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature) .
Conforms to UL Class 2.
Mounts to DIN Rail. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Tempeerature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E6B3-CWZ6C 20P/R 0.5M.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E6B3-CWZ6C 20P/R 0.5M.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.