Contact configuration: Four SPST-NO relays.
Heat sink: Yes.
Built-in SSRs: G3SD-Z01P-PD.
Zero cross function: No.
Applicable output load: 1 A at 3 to 26 VDC (See note 2.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit OMRON E6B3-CWZ5G 40P/R 2M.
Easy wiring with separate I/O terminal construction
E6B3-CWZ5G 40P/R 2M
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON E6B3-CWZ5G 40P/R 2M.
Shell color: silver.
Control output: current output .
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON E6B3-CWZ5G 40P/R 2M.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance .
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.215 A; 60 Hz, 0.190 A .
Rated input: 50 Hz, 20 W; 60 Hz, 18 W.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 66.6 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 ttype) and metal-bladed mmodels,
(28 type) included in series E6B3-CWZ5G 40P/R 2M.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffieed safety standards depend on the,
product E6B3-CWZ5G 40P/R 2M. Check the information given for available models of Axial fans and,
the information in Characteristics.
E6B3-CWZ5G 40P/R 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E6B3-CWZ5G 40P/R 2M&select=5