Safety outputs *1: Instantaneous, 2 (Semi conductors);
OFF-delayed*2, 2(Semiconductors).
Auxiliary outputs *3: 2 (Semi conductors).
Logical AND connection input: 1.
Logical AND connection output: 1.
Max. OFF delay time *4: 3.0 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Electronic Detection Mechanism for OMRON E5EC-QQ2ASM-000.
Better Stability in Non-contact Door.
Switch Operation. Contact configuration: Four SPST-NO relays
E5EC-QQ2ASM-000
Heat sink: No.
Built-in SSRs: G3SD-Z01P-PD.
Zero cross function: No.
Applicable output load: 0.6 A at 3 to 26 VDC(See note 2.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs OMRON E5EC-QQ2ASM-000.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit .
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Appearance: Round/Full-guard type LED lighting,
(without Voltage Reduction Unit) A22L-G.
Output: SPST-NC + SPST-NC OMRON E5EC-QQ2ASM-000.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Operation: Alternate operation (self-holding) .
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, suupport for a varietyy of applications E5EC-QQ2ASM-000.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5EC-QQ2ASM-000.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
E5EC-QQ2ASM-000 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5EC-QQ2ASM-000&select=5