Actuator: Adjustable rod lever.
Conduit openings: M20.
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts OMRON E2V-X8B1-M1TJ 0.3M.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
E2V-X8B1-M1TJ 0.3M
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion OMRON E2V-X8B1-M1TJ 0.3M.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) .
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Release key type: Trapped key *1.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO OMRON E2V-X8B1-M1TJ 0.3M.
Conduit opening: G1/2 .
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
iincluded in lineup . Sppecification: small E2V-X8B1-M1TJ 0.3M.
Impact resistance: 120W.
Resistance to impact resistance: 100.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttorr E2V-X8B1-M1TJ 0.3M.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.
E2V-X8B1-M1TJ 0.3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2V-X8B1-M1TJ 0.3M&select=5