Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available OMRON E2EH-X7C2-M1. )
M12-connector models are also available, saving on labor and,
simplifying replacement
E2EH-X7C2-M1
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON E2EH-X7C2-M1.
Certified standards: UL, EN (TÜV), and CCC. Receptacle box: G 1/2 Conduit .
Indicator: Without indicator.
Actuator: Top plunger, Adjustable.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type) OMRON E2EH-X7C2-M1.
Models with fluoro-rubber available for greater resistance to chemicals .
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Actuator: Adjustable roller lever.
Indicator: LED.
Item: Basic.
Pretravel (PT): 25±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point traansfer output andd remote SP input, suitable for a wide range of applications E2EH-X7C2-M1.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperratture controller is connected to each other by using the component communication E2EH-X7C2-M1.
A new type of proportional control allows you to control the valve.
E2EH-X7C2-M1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2EH-X7C2-M1&select=5