Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 100mm.
Output mode: PNP output. Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5V.
Insulation mode: three end two-way photoelectric switch OMRON E2E-C05S01-WC-C1 2M.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type)
E2E-C05S01-WC-C1 2M
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input OMRON E2E-C05S01-WC-C1 2M. Isolation method: Relay.
Zero cross function: No .
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations OMRON E2E-C05S01-WC-C1 2M.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Name: Wired Master.
Model: C200H-RM201.Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT .
Lightinng: Incandescent lamp, 28 VDC E2E-C05S01-WC-C1 2M.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
CCombines miniature design with distinct but soft sense of operation E2E-C05S01-WC-C1 2M.
Easy panel mounting from the front and simple lamp replacement.
without tools.
E2E-C05S01-WC-C1 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-C05S01-WC-C1 2M&select=5