Motor series: low inertia, medium power.
Rated output power: 15.0kw.
Rated speed: 1500r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: low inertia from low speed to high speed, three modes can be selected, suitable for different application range HC-SFS202BG1 1/6. As a standard port, 30KW or greater power is suitable for flange (type) installation and support foot mounting
HC-SFS202BG1 1/6
Application example: injection molding machine, semiconductor manufacturing equipment, large conveyor machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed HC-SFS202BG1 1/6.
All motor dimensions are the same as before and all are compatible with the wiring . Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 30VA.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter HC-SFS202BG1 1/6.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module .
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). JEMANET (OPCN-1) interface unit from the station.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. .
This phenomenon is called thee I/O delay time effect MITSUBISHI HC-SFS202BG1 1/6.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPUU MITSUBISHI HC-SFS202BG1 1/6.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
HC-SFS202BG1 1/6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SFS202BG1 1/6&select=5