Type: MR-J series.
Rated output: 0.2KW.
Applicable motor series: HA-FF, HA-SE.
Voltage: three phase AC220V.
It is very helpful to improve the stability of the low speed control of the servo motor.
But there is no direct effect to improve the accuracy of position control.
There are, of course, software compensation that is similar to pitch compensation,
Can improve the physical resolution of the single lap, so as to improve the accuracy of positioning control
FX-40DU-CAB
This can be effectively used in the use of the robot control of the indexing table.
It is also because of the application of splicing technology,
The rotary encoder will be more widely used in the high precision servo control in the harsh environment FX-40DU-CAB.
The use of rotary encoder with 224/ in the servo motor has been used in the servo motor.
Encoder serial communication system, the communication frequency can only be limited to 10M. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet FX-40DU-CAB.
Program capacity: 20K step.
Control mode: stored procedure repeated operation .
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "QnA/ACPU bus connection.
1 joint.
Applicable models: A985 (-V) /975/970/960GOT. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end.
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signaal transmission device, braake signal and fan fault signal MITSUBISHI FX-40DU-CAB.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI FX-40DU-CAB.
FX-40DU-CAB Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX-40DU-CAB&select=5