Motor series: low inertia, small capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.4kw.
Rated speed: 3000rpm.
With a brake band.
Shaft end: straight shaft.
AC servo motor and brushless DC servo motor in the function of the difference: AC servo is better, because it is a sine wave control, torque ripple small FR-RC-H30K.
DC servo is a trapezoidal wave. DC servo is simple and cheap
FR-RC-H30K Power: 75kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave.
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter FR-RC-H30K.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits .
Low noise.
No surge current.
Reduce motor loss (standard motor). AnS, QnAS bus connection, the reader to write program 2 channel connection.Input and output points: 1024 points.
Input / output data points: 1024 points FR-RC-H30K.
Program capacity: 14K.
Optical data communication line function (GI cable) .
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage cappacity: it is a measure off how much the user application can store the number of indicators MITSUBISHI FR-RC-H30K.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words MITSUBISHI FR-RC-H30K. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FR-RC-H30K Operation manual/Instructions/Model selection sample download link: