Sale FR-A840-09620-2-60 MITSUBISHI FR-A840-09620-2-60
No PHOTO
MITSUBISHI FR-A840-09620-2-60
MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 0.6kw.
Built in positioning function.
Voltage: 3 phase AC200VAC or single phase AC230V.
Super function, excellent performance.
High performance CPU integration, greatly improve product responsiveness.
Due to the application of high performance CPU, so that the response can be greatly improved FR-A840-09620-2-60.
Speed loop frequency response increased to more than 550HZ FR-A840-09620-2-60
MR-J2-Super series is the best device for high speed positioning applications.
Easy adjustment.
Model adaptive control / advanced real time automatic tuning. Input type: DC input, negative public end FR-A840-09620-2-60.
Input points: 16 points.
Enter the response time: 1.5ms the following .
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours.
Can be used for each 1 points to enter the wiring of the broken wire detection FR-A840-09620-2-60.
Wiring abnormality of external power supply can be confirmed .
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Output type: transistor source / drain type.
Output points: 8 points.
Load voltage: DC5/12/24/48.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Master / local station.
QnACPU use.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialiization procedure . After MITSUBISSHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system MITSUBISHI FR-A840-09620-2-60.
The main contents of the initialization program aree: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc MITSUBISHI FR-A840-09620-2-60. . "
FR-A840-09620-2-60 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-A840-09620-2-60&select=5