For the QnA/ACPU/ controller CPU (A Series) the bus (2 channel) thin type unit.
Applicable models: GT15, GT16. MELSECNET/10.
Inter-PC fiber loop. Output type: transistor output, source.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 AC20R4-A8PU. 5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup
AC20R4-A8PU
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AC20R4-A8PU. Input / output type: transistor output (source) .
Output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points AC20R4-A8PU. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to thhe master station via the nnetwork MITSUBISHI AC20R4-A8PU.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime. Cable length: 1.5 mmetters MITSUBISHI AC20R4-A8PU.
For FXCPU (FX0, FX0S, FX0N, FX1S, FX1N, FX2N, FX2NC,) and GOT connection.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connection.
AC20R4-A8PU Operation manual/Instructions/Model selection sample download link: