The input and output module installation number: 5.
Can install module: iQ-R MELSEC series module.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 245mm * 101mm.
Substrate module for mounting various modules of iQ-R MELSEC series.
CPU module could not be installed on the extended substrate module A9GT-QC300BS. "Max input / output points: 64 points.
Supply voltage: 100 - 240VAC
A9GT-QC300BS
Input points: 32 points.
Output points: 32 points.
Output type: transistor.
Power consumption: 60VA.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Note recording function, Component annotation can be recorded in the program register A9GT-QC300BS.
Online program editor, online change the program will not lose the working hours or stop production operation .
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard A9GT-QC300BS.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these sstandard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal MITSUBISHI A9GT-QC300BS.
So the standard telecommunication number, the conversiionn between the number of operations to use a variety of computing MITSUBISHI A9GT-QC300BS.
This requires the resolution of the analog unit and the standard electrical signal.