LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
Sale 61F-GP-NL 4KM AC220 OMRON 61F-GP-NL 4KM AC220
No PHOTO
OMRON 61F-GP-NL 4KM AC220
Operation indicator: With operating indication; Standard load.
Ratings: 4 A at 30 VDC.
Actuator: Adjustable rod lever.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models 61F-GP-NL 4KM AC220. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material 61F-GP-NL 4KM AC220
Cable lengths of 3 and 5 m available on standard models 61F-GP-NL 4KM AC220.
Models also available with UL and CSA-certified cables .
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Insulation method: Photocoupler 61F-GP-NL 4KM AC220.
Operation indicator: Yes (yellow).
Zero cross function: No.
Applicable output load: 75 A, 180 to 480 VAC .
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUNN/STOP, alarm), interactive display PV/SV OMRON 61F-GP-NL 4KM AC220.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation OMRON 61F-GP-NL 4KM AC220.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
61F-GP-NL 4KM AC220 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=61F-GP-NL 4KM AC220&select=5


...more relevant model market price >>>>