LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
Sale 400 MITSUBISHI 400
next one: MITSUBISHI AY40P
Last one: MITSUBISHI AY41P
MITSUBISHI 400
Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end 400.
36 point terminal station.
With short circuit protection.
With the surge absorber 400
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points 400.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process 400.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed,, smooth continuouss analog output MITSUBISHI 400.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulattedd according to the set conversion period MITSUBISHI 400.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
400 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=400&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Medium inertia power servo motor
HF-SP7024
MITSUBISHI Medium inertia power servo motor HF-SP7024
Servo motor series: medium inertia, medi
MITSUBISHI
Input / output mixed module
LH42C4PT1P-CM
MITSUBISHI Input / output mixed module LH42C4PT1P-CM
Input points: 32 points. Input voltage:
MITSUBISHI
3 phase 400V converter
FR-F740-S630K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-S630K-CHT
MITSUBISHI inverter FR-F740 series. Volt