MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 3.7kw.
SLD converter rated current: 25A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) MITSUBISHI Q172J2BCBL05M-B.
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment)
Q172J2BCBL05M-B
For applications that require high torque at low speeds, the HD rating is the most suitable MITSUBISHI Q172J2BCBL05M-B.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Servo motor series: low inertia, medium and large capacity MITSUBISHI Q172J2BCBL05M-B.
Rated output: 1.0kw.
Rated speed; 3000r/min.
Electromagnetic brake: incidental.
Power supply: 400V .
Most suitable for medium and large capacity, low inertia type products in high frequency operation or acceleration and deceleration operation.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage cappacity: it is a meassure of how much the user application can store the number of indicators Q172J2BCBL05M-B.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words Q172J2BCBL05M-B. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Q172J2BCBL05M-B Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Q172J2BCBL05M-B&select=5