LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
Q170MSCPU MITSUBISHI Q170MSCPU
MITSUBISHI Q170MSCPU
Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end MITSUBISHI Q170MSCPU.
36 point terminal station.
With short circuit protection.
With the surge absorber Q170MSCPU
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI Q170MSCPU.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI Q170MSCPU.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Type: 18 point terminal.
Input / output form: analog voltage and current input.
Number of stations: 1 stops.
Number of channels: 4 channels.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1 mu s/ channel.
The conversion speed of the analog output module is 100 mu s/ channel.
By combining the analog input module and the expansion module, the switching time can be controlled more precisely. (trigger conversion function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output deevices .
Can bbe connected to the expansion module, more convenient to expand the input and output points Q170MSCPU.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastterr) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station Q170MSCPU.
Q170MSCPU Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=Q170MSCPU&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Serial ABS synchronous encoder
Q170ENC
MITSUBISHI Serial ABS synchronous encoder Q170ENC
Resolution 262144PLS/res. Allow speed 36
MITSUBISHI
CPU unit
A2USCPU
MITSUBISHI CPU unit A2USCPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2SCPU
MITSUBISHI CPU unit A2SCPU
Program memory capacity 14K. Input and o
MITSUBISHI
Motion controller
Q170MSCPU-S1
MITSUBISHI Motion controller Q170MSCPU-S1
Control axis: up to 16 axes. Interpolati