LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
OMRON 70179-1009 LCM-150 70179-1009 LCM-150
No PHOTO
OMRON 70179-1009 LCM-150
Cable: With cable.
Connector: Connector on one cable end.
Cable length: 5 m.
Minimum order: 5.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock OMRON 70179-1009 LCM-150.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors 70179-1009 LCM-150
A full line-up of models is planned.
Connectors with Cables are UL approved. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON 70179-1009 LCM-150.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.190 A; 60 Hz, 0.160 A .
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2450 r/min; 60 Hz, 2700 r/min.
Maximum flow rate: 50 Hz, 2.2 m3/min; 60 Hz, 2.5 m3/min.
Maximum static pressure: 50 Hz, 63.7 Pa; 60 Hz, 63.7 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 42 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment OMRON 70179-1009 LCM-150.
Shaft supported by ball bearings for highly-reliable operation .
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate ttemperatures .
The cirrcuit section can be removed, so rewiring isn’t,
required during maintenance 70179-1009 LCM-150.
DIN track mounting. Operating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: L Series (tiimee range: 1 70179-1009 LCM-150. 0 to 120 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series.
70179-1009 LCM-150 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=70179-1009 LCM-150&select=5


...more relevant model market price >>>>