Type: KM50-C intelligent monitor.
Application circuit: single phase 2 wire system AC100 ~ 240V; single phase 3 wire system AC100/200V;
Three-phase 3 wire system AC100 ~ 240V.
Power supply voltage sharing: sharing AC100 to 240V with the measured voltage input.
Shape: 48 (H) * 48 (W) * 84 (D).
Communication: RS-485 70156-3015 MS46SR-30-870-Q1-00 Price.
Protocol: ompoWay/F: the number of communication nodes 31 Modbus: the number of communication nodes 99 (shared)
70156-3015 MS46SR-30-870-Q1-00
Energy classification function (industry initiative).
Show the 3-STATE function through the 3 color display energy saving room for improvement.
Equipped with easy to grasp the room for energy saving and convenient 3-STATE function 70156-3015 MS46SR-30-870-Q1-00 Price.
3-STATE function refers to the use of the state power, the cumulative power is divided into operation / standby / stop 3 types of functions .
2 and 3-STATE function linkage, can operate / standby / stop 3 points for individual output
(determine the object can be selected from power, current, voltage)
Pulse input count, pulse input ON time, unit power consumption measurement 70156-3015 MS46SR-30-870-Q1-00 Price. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC .
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 5 V.
Output current: 7 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safetty standards: UL 508/60950-1, cUL CSA C222 OMRON 70156-3015 MS46SR-30-870-Q1-00.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply OMRON 70156-3015 MS46SR-30-870-Q1-00. ).
70156-3015 MS46SR-30-870-Q1-00 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70156-3015 MS46SR-30-870-Q1-00&select=5