Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function 44534-2090 TL4019-30243 Price.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input
44534-2090 TL4019-30243
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure 44534-2090 TL4019-30243 Price.
High resolution 5 bit display / can display 0.01 degrees C .
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV 44534-2090 TL4019-30243 Price.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output .
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Actuator: Arm lever.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic--body Safety-door .
Hinge Switch Designed for Saving OMRON 44534-2090 TL4019-30243.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBBB ccontacts are also available OMRON 44534-2090 TL4019-30243.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
44534-2090 TL4019-30243 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44534-2090 TL4019-30243&select=5