Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross 1VE-10CA-12 Price.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection
1VE-10CA-12 The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters 1VE-10CA-12 Price.
Combining with special CT for150-A current detection .
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 22 dia.
Protective tubing length L: 50 cm.
A Wide Variety of High-precision 1VE-10CA-12 Price.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work .
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON 1VE-10CA-12.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON 1VE-10CA-12.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
1VE-10CA-12 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=1VE-10CA-12&select=5