Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations
ZR-SX10
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature OMRON .
Operation indicators to easily check operation .
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Model: P2R (back-mounting), pages 11 and 12, PCB terminals.
Approx: 5.5 g.
Number of pins: 5 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection OMRON .
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The prootection coordinattion between OCR and MCCB is simple OMRON ZR-SX10.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident OMRON ZR-SX10.
Reduce the consumption of VA, reduce the burden of converter.
ZR-SX10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=ZR-SX10&select=5