LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
MITSUBISHI Q173J2B4CBL05M Q173J2B4CBL05M
No PHOTO
MITSUBISHI Q173J2B4CBL05M
Cable length: 20m.
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-SFS; HC-LFS; HC-RFS; 2000r/min HA-LFS; HC-UFS servo motor.
-H products have a long flex life.
Coding is not resistant to oil.
Input type: DC input, positive common end.
Input points: 16 points.
Input response time: 0.5ms below /1.5ms MITSUBISHI Q173J2B4CBL05M.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type Q173J2B4CBL05M
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. 8 slots.
Power supply unit.
QnAS series unit installation.
High speed access.
I/O points is an important indicator of PLC MITSUBISHI Q173J2B4CBL05M.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest .
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI Q173J2B4CBL05M.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30% .
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action. Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also bee processed outsidee the standard control procedures Q173J2B4CBL05M.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,

Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q173J2B4CBL05M.
Q173J2B4CBL05M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=Q173J2B4CBL05M&select=5


...more relevant model market price >>>>
Related products