LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
MITSUBISHI HC-MFS/KFS053BG2 (1/5) Price HC-MFS/KFS053BG2 (1/5)
No PHOTO
MITSUBISHI HC-MFS/KFS053BG2 (1/5)
CC-link remote device station.
CC-link/LT master function.
Consumption current: 75mA (DC24V, power supply through the power adapter)
Current at startup: 165mA (DC24V, power supply through the power adapter)
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc HC-MFS/KFS053BG2 (1/5) Price. .
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses HC-MFS/KFS053BG2 (1/5)
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc HC-MFS/KFS053BG2 (1/5) Price. ,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system HC-MFS/KFS053BG2 (1/5) Price.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information. Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect thee abnormal detection function of the iinput signal which is outside the range of the set range MITSUBISHI HC-MFS/KFS053BG2 (1/5).
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter ranngee extension
Range of scalable input range MITSUBISHI HC-MFS/KFS053BG2 (1/5).
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.
HC-MFS/KFS053BG2 (1/5) Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=HC-MFS/KFS053BG2 (1/5)&select=5


...more relevant model market price >>>>
Related products