Input / output type: DC input (drain / source).
Input and output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 50mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 MITSUBISHI FX3U-20SSC-H.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points
FX3U-20SSC-H Output points: 8 points.
Output voltage and current: 2A/1; DC24V/AC240V point.
Response time: 12ms.
18 point terminal station.
Full independent contact MITSUBISHI FX3U-20SSC-H.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function .
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users MITSUBISHI FX3U-20SSC-H.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights .
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the nettwork settings caan easily establish a connection FX3U-20SSC-H.Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Sennsoor connection type FX3U-20SSC-H.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.
FX3U-20SSC-H Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3U-20SSC-H&select=5