MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 1.0kw.
SSCNET interface.
Voltage: 3 phase AC200VAC or single phase AC230V.
Complete synchronization system with SSCNET high speed serial communication,
The communication cycle between the controller and the servo amplifier is the longest 0 MITSUBISHI FX1S-20MT-DSS. 888ms.
Such systems will be able to provide high reliability and high performance
FX1S-20MT-DSS
When connecting the servo system with SSCNET,
In the motion system, the parameters of the servo amplifier and the acquisition of the data will be displayed on the motion controller.
Connect a dedicated cable with an amplifier and a controller to form a SSCNET system MITSUBISHI FX1S-20MT-DSS.
This simple connection method reduces the routing time and helps to prevent noise .
Even in the MELSERVO-J2-SUPER series products using high resolution coding standards, the command frequency is no limit.
It is only necessary to add a battery on the servo amplifier, which can form the absolute value system.
Currently there are more than 1000000 high reliability SSCNET servo amplifier networks in use MITSUBISHI FX1S-20MT-DSS. Application: extension .
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Cable length: 20m.
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-SFS; HC-LFS; HC-RFS; 2000r/min HA-LFS; HC-UFS servo motor.
-H products have a long flex life.
Coding is not resistant to oil.
Input voltage range: AC100 ~ 120V/AC200 ~ 240V.
Output voltage: DC5/12V.
Output current: 2.3A/1.5A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load currrent and voltage FX1S-20MT-DSS.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load FX1S-20MT-DSS.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
FX1S-20MT-DSS Operation manual/Instructions/Model selection sample download link: