Maximum frequency: 200kHz.
Input points: 2 points.
Output form: transistor 4 point output.
Weight: 0.2kg.
1 FX3U-2HC can enter the 2CH high speed signal, can achieve the maximum count of 200kHz.
Through the comparison of the value of the PLC set, each ch with 2 points of high-speed output terminal.
In the 2 phase count, can be set 1, 2, 4 frequency MITSUBISHI .
Can be achieved by PLC or external input to count the licensing / prohibition
Q64DAH
Can also be connected to the linear drive output type of the encoder.
FX3UC host connected to the FX2NC-CNV-IF, the need for FX3U-2HC or FX3UC-IPS-5V. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0 MITSUBISHI . 1mA.
Output type: transistor output (type sink).
Response time: 2ms .
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal MITSUBISHI .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI Q64DAH MITSUBISHI Q64DAH.