Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0 MITSUBISHI . 1A.
External connection: 1 line /1 line type.
Fast connector type.
Simple wiring through quick connector
Q173HBCBL5M
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI .
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Bus connection (1 channel) unit standard model for QnA/ACPU/ transport controller CPU (A series).
Applicable models: GT15, GT16. Motor series: low inertia, medium capacity MITSUBISHI .
Rated output power: 15.0kw.
Rated speed: 1000rpm.
With the brake: without .
Shaft end: straight shaft.
The rotor of the servo motor is a permanent magnet, which is controlled by the U/V/W,
The rotor rotates under the action of the magnetic field, and the encoder feedback signal of the motor is given to the driver,
According to the feedback value and the target value, the driver adjusts the rotation angle of the rotor.
Accuracy of the servo motor depends on the accuracy of the encoder (number of lines). Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DAC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Coaxial data communication line function.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators MITSUBISHI Q173HBCBL5M.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words MITSUBISHI Q173HBCBL5M. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.