Input points: 32 points
Input mode: DC24V (drain type).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points
GT16-70PSGB With 4.3 inch widescreen.
Applicable model: GT21. Terminal connectorFor HF-KP/HF-MP series"4 axes, SSCNET connection type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse MITSUBISHI GT16-70PSGB.
Location data: 600 data / axis.
40 pin connector.
Easy to achieve high speed, high precision positioning control .
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc..
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug MITSUBISHI GT16-70PSGB.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m .
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin.
No need for the near point block, such as wiring. "Output points: 16 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeeting the controol requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC GT16-70PSGB.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation GT16-70PSGB.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
GT16-70PSGB Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT16-70PSGB&select=5