Support for 10.4 inch /8.4 inch.
Applicable models: GT16, GT15. Motor series: medium inertia, medium power.
Rated output power: 2.0kw.
Rated speed: 1000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: medium inertia from low speed to high speed three modes for selection, suitable for different applications MITSUBISHI A956GOT-LBD.
Application examples: transmission machinery, robots, X-Y working platform
A956GOT-LBD
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring MITSUBISHI A956GOT-LBD. Pulse input: differential input .
Default input: DC input.
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration MITSUBISHI A956GOT-LBD.
A local PLC can communicate with the master station PLC and other remote workstations .
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to furtherr carry on the oon-line unification to adjust A956GOT-LBD.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp bby step A956GOT-LBD.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
A956GOT-LBD Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A956GOT-LBD&select=5