Model: C200H-ID111.
No. of points: 64 pts.
Specifications: 12VDC.
Weight: 250g max.Connection method: Pre-wired.
Cable length: 2 m.
Sensing distance: 600 ± 400 mm.
Model: NPN output.
A CMOS Laser Sensor That’s.
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments OMRON 70177-1681 SGE-225-0-0920N 050.
Stable measurements for any type of workpiece.
Models available with four different distance specifications
70177-1681 SGE-225-0-0920N 050
Long-distance model for up to 1,000 mm. Cable length L: A, 5.0 m; B, 4.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch OMRON 70177-1681 SGE-225-0-0920N 050. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with .
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON 70177-1681 SGE-225-0-0920N 050.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution .
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily setSize: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOPP, alarm), interactive display PV/SV 70177-1681 SGE-225-0-0920N 050.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation 70177-1681 SGE-225-0-0920N 050.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
70177-1681 SGE-225-0-0920N 050 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70177-1681 SGE-225-0-0920N 050&select=5