Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross OMRON 70177-1646 SGE-225-0-0890 0500.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection
70177-1646 SGE-225-0-0890 0500 The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters OMRON 70177-1646 SGE-225-0-0890 0500.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection .
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release OMRON 70177-1646 SGE-225-0-0890 0500.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ .
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the proceess of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output 70177-1646 SGE-225-0-0890 0500.
Through the infrared port can be carried out from the frronnt of the communication 70177-1646 SGE-225-0-0890 0500.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
70177-1646 SGE-225-0-0890 0500 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=70177-1646 SGE-225-0-0890 0500&select=5